u
Changing Parameter Settings or Values
This example explains changing C1-01 (Acceleration Time 1) from 10.0 seconds (default) to 20.0 seconds.
Step
Display/Result
1.
Turn on the power to the drive. The initial display appears.
2.
Press the
key until the Setup Mode Screen appears.
3.
Press the
key to view the parameter setting display.
4.
Scroll through parameters by pressing the
key until C1-01 appears.
5.
Press
to view the current setting value (10.0). (Number farthest to the left flashes)
6.
Press
until the desired number is selected. (“1” flashes)
7.
Press the
key and enter 0020.0.
8.
Press
and the drive will confirm the change.
9.
The display automatically returns to the screen shown in Step 4.
10.
Press the
key until back at the initial display.
u
Verifying Parameter Changes: Verify Menu
The Verify Menu lists edited parameters from the Programming Mode or as a result of Auto-Tuning. The Verify Menu helps
determine which settings have been changed, and is particularly useful when replacing a drive. If no settings have been changed,
the Verify Menu will read
. The Verify menu also allows users to access and re-edit previously edited parameters.
Note:
The Verify Menu will not display A1-
oo
parameters (except for A1-02), nor will it display parameters A2-01 to A2-32 or E5-01 even if
those parameters have been changed from default settings.
The following example is a continuation of the steps beginning on page
. Here, parameter C1-01 is accessed using the Verify
Menu and is changed again to 20.0 s.
To check the list of edited parameters:
Step
Display/Result
1.
Turn on the power to the drive. The initial display appears.
2.
Press
until the display shows the “Verify” representation.
3.
Press
to enter the list of parameters that have been edited from their original default
settings.
Scroll through the list by pressing the
key.
4.
Press the
key until C1-01 appears.
5.
Press the
key to access the setting value. (number farthest to the left flashes)
u
Switching Between LOCAL and REMOTE
Entering the run command using the LED operator is referred to as LOCAL, while entering the run command from an external
device via the control circuit terminals or network option is referred to as REMOTE.
WARNING! Sudden Movement Hazard. The drive may start unexpectedly if the Run command is already applied when switching from
LOCAL mode to REMOTE mode when b1-07 = 1, resulting in death or serious injury. Be sure all personnel are clear of rotating machinery
and electrical connections prior to switching between LOCAL mode and REMOTE mode.
There are two ways to switch between LOCAL and REMOTE.
Note:
1.
After selecting LOCAL, the LO/RE light will remain lit.
4.3 The Drive and Programming Modes
88
YASKAWA ELECTRIC SIEP C710606 18F YASKAWA AC Drive – V1000 Technical Manual