n
Drive Software Version PRG: 1018 and Later
Table B.15 200 V, 1450 rpm Type Yaskawa SSR1 Series Motor
Par.
Description
Unit
Default Settings
E5-01
Motor Code
−
1302
1303
1305
1306
1308
130A
130B
130D
130E
130F
Voltage Class
−
200 Vac
200 Vac
200 Vac
200 Vac
200 Vac
200 Vac
200 Vac
200 Vac
200 Vac
200 Vac
Rated Power
−
0.4 kW
0.75 kW
1.5 kW
2.2 kW
3.7 kW
5.5 kW
7.5 kW
11 kW
15 kW
18 kW
Rated Speed
r/min
1450
1450
1450
1450
1450
1450
1450
1450
1450
1450
E5-02 Motor Rated Power
kW
0.4
0.75
1.5
2.2
3.7
5.5
7.5
11
15
18.5
E5-03 Motor Rated Current
A
1.88
3.13
5.63
8.33
14.17
20.63
27.71
39.6
55.5
65.6
E5-04 Motor Pole Number
–
6
6
6
6
6
6
6
6
6
6
E5-05
Motor Winding
Resistance
Ω
3.190
1.940
1.206
0.665
0.341
0.252
0.184
0.099
0.075
0.057
E5-06 d-Axis Inductance
mH
32.15
26.12
14.72
12.27
8.27
6.49
6.91
4.07
3.29
2.53
E5-07 q-Axis Inductance
mH
41.74
34.3
20.15
14.77
9.81
7.74
7.66
4.65
3.84
3.01
E5-09
Induction Voltage
Constant 1
mVs/rad
264.3
269.6
284.3
287.1
284.5
298.0
335.0
303.9
311.2
300.9
E5-24
Induction Voltage
Constant 2
mV/(r/
min)
0
0
0
0
0
0
0
0
0
0
E1-04
Maximum Output
Frequency
Hz
72.5
72.5
72.5
72.5
72.5
72.5
72.5
72.5
72.5
72.5
E1-05
Maximum Output
Voltage
V
190
190
190
190
190
190
190
190
190
190
E1-06 Base Frequency
Hz
72.5
72.5
72.5
72.5
72.5
72.5
72.5
72.5
72.5
72.5
E1-09
Minimum Output
Frequency
Hz
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
L3-24
<1>
Motor Acceleration
Time for Inertia
Calculations
s
0.098
0.071
0.066
0.087
0.085
0.072
0.084
0.096
0.085
0.08
n8-49
d-Axis Current for
High-Efficiency
Control
%
–6.6
–10.9
–13.5
–9
–9.5
–10.1
–6
–9.3
–10.7
–13.2
<1> Default setting value is dependent on parameter o2-04, Drive Model Selection.
B.6 Parameters that Change with the Motor Code Selection
YASKAWA ELECTRIC SIEP C710606 18F YASKAWA AC Drive – V1000 Technical Manual
423