n
Rated Current Depending on Carrier Frequency
The tables below show the drive output current depending on the carrier frequency settings. The 2 kHz value is equal to the
Normal Duty rated current, the 8/10 kHz value is equal to the Heavy Duty rated current. The carrier frequency determines the
output current linearly. Use the data below to calculate output current values for carrier frequencies not listed in the tables.
Note:
In Heavy Duty mode the maximum rated output current is equal to the 8/10 kHz value, even if the carrier frequency is reduced.
Table 5.12 200 V Class Drives with 10 kHz Heavy Duty Default Carrier Frequency
Model
Rated Current (A)
2 kHz
10 kHz
15 kHz
BA0001
2A0001
1.2
0.8
0.6
BA0002
2A0002
1.9
1.6
1.3
BA0003
2A0004
3.5
3.0
2.4
BA0006
2A0006
6.0
5.0
4.0
Table 5.13 200 V Class Drives with 8 kHz Heavy Duty Default Carrier Frequency
Model
Rated Current (A)
2 kHz
8 kHz
15 kHz
BA0010
2A0010
9.6
8.0
6.4
BA0012
2A0012
12.0
11.0
8.8
BA0018
17.5
17.5
14.0
2A0020
19.6
17.5
14.0
2A0030
30.0
25.0
20.0
2A0040
40.0
33.0
26.4
2A0056
56.0
47.0
37.6
2A0069
69.0
60.0
48.0
Table 5.14 400 V Class Drives with 8 kHz Heavy Duty Default Carrier Frequency
Model
Rated Current (A)
2 kHz
8 kHz
15 kHz
4A0001
1.2
1.2
0.7
4A0002
2.1
1.8
1.1
4A0004
4.1
3.4
2.0
4A0005
5.4
4.8
2.9
4A0007
6.9
5.5
3.3
4A0009
8.8
7.2
4.3
4A0011
11.1
9.2
5.5
4A0018
17.5
14.8
8.9
4A0023
23.0
18.0
10.8
4A0031
31.0
24.0
14.4
4A0038
38.0
31.0
18.6
5.3 C: Tuning
158