Table A.3 Power Ratings Continued
Item
Specification
Three-Phase Model
2A0030
2A0040
2A0056
2A0069
Single-Phase Model
<1>
-
-
-
-
Maximum Motor Size Allowed (HP)
<2>
ND Rating
7.5/10.0
10.0
20.0
25.0
HD Rating
7.5
10.0
15.0
20.0
Input
Input Current (A)
<3>
Three-
Phase
ND Rating
37.0
52.0
68.0
80.0
HD Rating
24.0
37.0
52.0
68.0
Single-
Phase
ND Rating
-
-
-
-
HD Rating
-
-
-
-
Output
Rated Output Capacity (kVA)
<4>
ND Rating
11.4
15.2
21.3
26.3
HD Rating
9.5
12.6
17.9
22.9
Output Current (A)
ND Rating
<5>
30.0
40.0
56.0
69.0
HD Rating
25.0
<6>
33.0
<6>
47. 0
<6>
60.0
<6>
Overload Tolerance
ND Rating: 120% of rated output current for 1 minute
HD Rating: 150% of rated output current for 1 minute
(Derating may be required for applications that start and stop frequently)
Carrier Frequency
User-adjustable 2 to 15 kHz
Max Output Voltage (V)
Three-phase power: 200 to 240 V
Single-phase power: 200 to 240 V
(both proportional to input voltage)
Max Output Frequency (Hz)
400 Hz (user-adjustable)
Power
Supply
Rated Voltage
Rated Frequency
Three-phase power: 200 to 240 V 50/60 Hz
Single-phase power: 200 to 240 V 50/60 Hz
DC power supply: 270 to 340 V
<7>
Allowable Voltage Fluctuation
-15 to 10%
Allowable Frequency Fluctuation
±5%
Harmonic Corrective Actions
DC Link Choke
Optional
<1> Drives with single-phase power supply input will output three-phase power and cannot run a single-phase motor.
<2> The motor capacity (HP) refers to a NEC rated 4-pole motor. The rated output current of the drive output amps should be equal to or greater than
the motor rated current.
<3> Input current rating varies depending on the power supply transformer, input reactor, wiring connections, and power supply impedance.
<4> Rated motor capacity is calculated with a rated output voltage of 220 V.
<5> Carrier frequency is set to 2 kHz (Swing PWM). Current derating is required in order to raise the carrier frequency.
<6> Carrier frequency is set to 8 kHz. Current derating is required in order to raise the carrier frequency.
<7> DC is not available for UL standards.
A.2 Single/Three-Phase 200 V Class Drives
344
YASKAWA ELECTRIC SIEP C710606 18F YASKAWA AC Drive – V1000 Technical Manual