u
Copy Function (Optional)
Parameter settings can be copied to another drive to simplify parameter restoration or multiple drive setup. The drive supports
the following options:
n
USB/Copy Unit (JVOP-181)
The copy unit is an external option connected to the drive to copy parameter settings to another drive. It includes a USB adapter
to connect the drive to a PC.
n
LCD Operator (JVOP-180)
The LCD operator operates the drive and supports copying, importing, and verifying parameter settings using the parameters
o3-01 and o3-02.
Note:
Use of the LCD operator requires that the drive is running drive software version PRG: 1012 or later. The LCD operator is not compatible
with drive software version PRG: 5010.
n
LED Operator (JVOP-182)
The LED operator operates the drive and supports copying, importing, and verifying parameter settings.
Note:
Use of the LED operator requires that the drive is running drive software version PRG: 1014 or later. The LED operator is not compatible
with version PRG: 5010.
n
Drive Wizard Plus
Drive Wizard Plus is a PC software tool for parameter management, monitoring, and diagnosis. Drive Wizard Plus can load,
store, and copy drive parameter settings. For details, refer to Help in the Drive Wizard Plus software.
The installation files can be obtained at no charge from:
U.S.: http://www.yaskawa.com
4.10 Verifying Parameter Settings and Backing Up Changes
YASKAWA ELECTRIC SIEP C710606 18F YASKAWA AC Drive – V1000 Technical Manual
111
4
Start-Up Programming & Operation