Table 3.16 Braking Resistor Settings
Parameter
Settings
L8-01: Internal Dynamic Braking Resistor Protection Selection
0: Disabled. The drive will not provide overheat protection.
Supply separate means of overheat protection.
1: Enabled. Braking Resistor is protected from overheat.
L3-04: Stall Prevention During Deceleration
Note:
Select either 0 or 3
0: Stall prevention disabled.
3: Stall prevention enabled with a braking resistor
Note:
This setting cannot be used in OLV control for PM
motor.
8.
Operate the system and verify the required deceleration rate is obtained during dynamic braking or stopping.
3.11 Braking Resistor
YASKAWA ELECTRIC SIEP C710606 18F YASKAWA AC Drive – V1000 Technical Manual
73
3