Technical requirements for the repaired assembly unit
1 Circular runout tolerance of the surface B relatively to the general surface axis A and Д – 0.01 mm
2 Roughness of the surfaces А and Д should not exceed Ra 0.63 micron according to the GOST 2789-73
Name of the part or assembly unit
Marking
Flow regulation valve
Release valve
236-1011048-
Б
236-1011363-
Б2
Material
Hardness
-
-
N
um
be
r o
f t
he
d
ef
ect
L
oc
at
ion o
f t
he
p
ic
tu
re
Possible defect
Way for defect detection
and means of control
Dimension and parameter, mm
Conclusion
nominal
maximum allowable
without repair
for repair
1
Б
Mechanical damagesor wear of the parts
Test stand
Leakage under the pressure
-
0.05 МPа 0.5 kfg/cm
2
no more than 2.5 l/min
-
To reject