1
2
-
-
Cracks on the walls of the
cooling jacket, gas passages or
joining surface to the cylinder
block
Cracks, touchingholes for the
guides valve bushings, nozzle
barrels and seats of the valves
Inspection.
Tests for
sealing with water pressure
0.3-0.4 MPa
(3-4 kfg/cm ) during 2 min
Inspection.
Tests for
sealing with water pressure
0.3-0.4 MPa
(3-4 kfg/cm ) during 2 min
Water or kerosene leakage is not permitted
Water or kerosene leakage is not permitted
-
-
To weld
To reject