6 - 7
–
+
ELEC
ELECTRIC STARTING SYSTEM
(TT-R90E)
STARTING CIRCUIT CUT-OFF SYSTEM
OPERATION
If the main switch is set to “ON”, the starter
motor can only operate if the following condi-
tion is met:
• The transmission is in neutral (the neutral
switch is closed).
The starting circuit cut-off relay prevents the
starter motor from operating when this condi-
tion has not been met. In this instance, the
starting circuit cut-off relay is open so current
cannot reach the starter motor. When the
above condition has been met the starting cir-
cuit cut-off relay is closed and the engine can
be started by pressing the start switch.
WHEN THE TRANSMISSION IS
IN NEUTRAL
1
Battery
2
Main fuse
3
Main switch
4
Start switch
5
Starting circuit cut-off relay
6
Neutral switch
7
Starter relay
8
Starter motor
1
2
M
3
7
5
4
6
8
ELECTRIC STARTING SYSTEM (TT-R90E)