4 - 51
ENG
OIL PUMP
INSPECTION
Oil pump
1. Inspect:
●
Oil pump drive gear
●
Oil pump driven gear
●
Oil pump housing
●
Oil pump cover
Cracks/wear/damage
→
Replace.
2. Measure:
●
Tip clearance
Å
(between the inner rotor
1
and the
outer rotor
2
)
●
Side clearance
ı
(between the outer rotor
2
and the oil
pump housing
3
)
Out of specification
→
Replace the oil
pump assembly.
●
Housing and rotor clearance
Ç
(between the pump housing
3
and the
rotors
1
2
)
Out of specification
→
Replace the oil
pump assembly.
Tip clearance
Å
:
0.15 mm (0.0059 in)
<Limit>: 0.20 mm (0.0079 in)
Side clearance
ı
:
0.06 ~ 0.10 mm
(0.0024 ~ 0.0039 in)
<Limit>: 0.15 mm (0.0059 in)
Housing and rotor clearance
Ç
:
0.06 ~ 0.10 mm
(0.0024 ~ 0.0039 in)
<Limit>: 0.15 mm (0.0059 in)
Rotary filter
1. Inspect:
●
Rotary filter
Cracks/damage
→
Replace.