2-51
INSP
ADJ
Charging method using a constant voltage charger
Measure the open-circuit
voltage prior to charging.
NOTE:
Set the charging time at 20 hours
(maximum).
Connect a charger and
AMP meter to the battery
and start charging.
Make sure that the current
is higher than the stan-
dard charging current writ-
ten on the battery.
Charge the battery until the battery’s
charging voltage is 15 V.
This type of battery charger cannot
charge the MF battery. A variable
voltage charger is recommended.
Measure the battery open-circuit voltage
after leaving the battery unused for more
than 30 minutes.
12.8 V or more --- Charging is complete.
12.7 V or less --- Recharging is required.
Under 12.0 V --- Replace the battery.
NOTE:
Voltage should be measured 30
minutes after the snowmobile is
stopped.
Charger
AMP meter
Volt meter
NO
YES