8-16
–
+
ELEC
Inspection
1. Inspect:
• Commutator (outer surface)
Dirty
→
Clean with #600 grit sandpaper
1
.
Hold the armature in a vise
2
and copper or
aluminium plate
3
.
CAUTION:
Lightly grip the armature with a vise.
2. Measure:
• Commutator diameter
a
Measure the diameter
a
of the commutator at
points where the brush comes in contact.
Out of specification
→
Replace the starter
motor.
Commutator diameter wear limit:
27.0 mm (1.06 in)
3. Measure:
• Mica undercut (insulation depth)
a
(between commutator segments)
Out of specification
→
Scrape mica
1
to
proper limits.
Use a hacksaw blade
2
that is ground to fit.
Mica undercut:
1.0 mm (0.04 in)
4. Measure:
• Armature coil resistance
(insulation/continuity)
Out of specification
→
Replace the starter
motor.
Inspecting steps:
• Connect the pocket tester for the continuity
check
1
and the insulation check
2
.
• Measure the armature coil resistances.
• If the resistance is incorrect, replace the starter
motor.
Armature coil resistance:
Continuity check:
0.0081 ~ 0.0099
Ω
at 20 °C (68 °F)
Insulation check:
Above 1 M
Ω
at 20 °C (68 °F)
Summary of Contents for FX10X 2008
Page 2: ......
Page 312: ...7 36 FI ...
Page 333: ...8 21 ELEC CHARGING SYSTEM ...
Page 341: ...8 29 ELEC LIGHTING SYSTEM ...
Page 404: ...9 43 SPEC CABLE ROUTING 9 1 2 3 4 5 6 6 7 7 8 ...
Page 406: ......
Page 407: ......