DME Manager Error Messages
271
DME32—Owner’s Manual
DME Manager Error Messages
If DME Manager displays an error message, look for the solution in the following table.
Message
Reason
Solution
Cannot compile because
configuration contains no
components!
An attempt was made to compile a con-
figuration that contains no compo-
nents.
Add some components, and then try
compiling again.
Cannot display more than
32 meters!
An attempt was made to display more
than 32 meters.
A maximum of 32 meters can be dis-
played simultaneously.
COM port open error 5
The COM port is in use by another
device.
Disable the device using the COM port.
Open the “setup.ini” file in the DME
folder and make sure that the COM set-
ting is correct. If you are using com port
2, for example, the setting should be
“COM2”.
Component position
error!
An error occurred while trying to dis-
play the configuration.
Try opening the configuration again, or
try receiving it from the DME32 again.
Configuration must be
compiled before saving!
An attempt was made to save a config-
uration that has not been compiled.
Compile the configuration, and then try
saving again.
Configuration must be
compiled before sending!
An attempt was made to send an
uncompiled configuration to the
DME32.
Compile the configuration, and then try
sending again.
DME32 and DME Manager
configurations do not
match!
The DME Manager and DME32 config-
uration data does not match.
Match the data, and then try sending
the configuration again.
DME32 not found!
The DME32 was not detected when
DME Manager was started.
Continue using only DME Manager, or
check the DME32 connection and
restart DME Manager.
Error reading file!
An error occurred while trying to open
a file. Perhaps the file is already in use,
or has not yet been saved.
Check if the file is already in use, or
check if it has been saved, and then try
opening again.
Error receiving
configuration!
An error occurred while receiving a con-
figuration from the DME32.
Check the DME32 connection, and then
try receiving again.
Error sending
configuration!
An error occurred while sending a con-
figuration to the DME32.
Check the DME32 connection, and then
try sending again.
Error writing file!
An error occurred while trying to write
to a file. Perhaps it's in use, or is write
protected.
Enter another file name, or turn off the
write protection, and then try saving
again.
Grid spacing is too large
or too small!
The specified grid spacing is too large
or too small.
Enter a grid spacing within the valid
range.
Incorrect password!
The password entered was incorrect.
Enter the correct password.
No configuration selected!
An attempt was made to send a config-
uration, but no configuration was
selected.
Select a configuration, and then try
sending again.
“NO DATA” is an invalid
file name!
“NO DATA” cannot be used as a file
name.
Enter a file name other than “NO
DATA”.
Not a DME file!
An attempt was made to open a file
other than a DME file.
Open, and drag open only DME files
Printer setup error!
An error occurred while trying to read
the printer setup information. Perhaps
the printer is not set up correctly, or a
suitable driver is not available.
Set up the printer correctly.