114
Chapter 8—Component Guide Part I
DME32—Owner’s Manual
The Delay parameters for all channels are explained in the following table.
In the DELAY SCALE section, “FS” indicates the selected wordclock frequency, and
“340 m/s” and “1,115.5 ft/s” are the speed of sound in meters and feet respectively (air
temperature = 14˚C, 57.2˚F).
The parameter ranges for the Sample, m, and feet settings are as follows:
Cross
The CROSS page features the 4-way crossover controls and crossover graph.
Note that the Gc controls (not shown here) appear only when an Adjustable Gc type
SLOPE & TYPE filter is selected.
The crossover graph at the top of the window displays the crossover settings graphically.
A vertical dotted line indicates the crossover frequency of each channel: “L” for low,
“ML” for low-mid, “MH” for high-mid, and “H” for high.
Section
Parameter
Range
Description
LOW,
LOW-MID,
HIGH-MID,
HIGH
ms
0.0–500.0 ms
Sets the delay time in milliseconds
(linked to control below)
Sample
1
1. This control’s label depends on the Delay Scale setting.
See the following
table
Sets the delay time in the units chosen
using the DELAY SCALE buttons (linked
to ms control)
ON/OFF
ON/OFF
Turns the delay on and off
DELAY SCALE
See the following
table
Selects the delay units for the Sample
controls
Delay Scale
FS = 48 KHz
FS = 44.1 kHz
Samples
0–24000 samples
0–22050 samples
Meters
0.0–170.0 meters
Feet
0.0–557.8 feet