Delay
There are eight components in the Delay group, each with one input and from one to
eight outputs. These are multi-tap delays, with independent delay and level controls for
each output. Delay times can be specified in milliseconds and other units, including,
samples, meters, feet, timecode frames, or beats per minute.
Since the only difference between all the Delay components is the number of outputs,
only the Delay 4 Out control window is shown here.
Each Delay control window features a DELAY SCALE button, INPUT section, and
delay control section.
The DELAY SCALE button opens the Delay Scale window, which is used to select the
delay time units. See “Setting the Delay Scale” on page 121 for more information.
In addition to dragging the delay time controls, delay times can be specified using the
computer keyboard. Simply select the value below a control using the mouse, enter a
value from the keyboard, and then press the Enter key. The new value is set and the
rotary controls move to their new positions.
Section Parameter
Range
Description
ON/OFF
ON/OFF
Turns the component on and off
INPUT
LEVEL
–Infinity dB to 0.0 dB
Adjusts the input signal level
MUTE
ON/OFF
Mutes the input