Summary of Contents for MPR 1500

Page 1: ...nsmitteltechnik Translation of the original instructions Miknetum Type MPR 1500 Rühle GmbH Beim Signauer Schachen 10 D 79865 Grafenhausen Telephone 49 7748 523 11 Fax 49 7748 523 8511 www original ruehle de ...

Page 2: ...3 Operating instructions 9 4 Cleaning instructions 12 4 1 Safety instructions 12 4 2 Cleaning agents and disinfectants 13 4 3 Cleaning procedure 14 5 Service Care maintenance repair 14 5 1 Regular care 15 5 2 Regular maintenance 16 5 3 Repair and spare parts 16 6 Disposal 16 7 Technical documentation 17 7 1 Technical data 17 7 2 Electrical circuit diagram 18 8 EC Declaration of Conformity accordin...

Page 3: ...y qualified technicians Always disconnect machine from the mains during this process Refrigeration installer These work activities may be carried out only by a re frigeration installer Disregard may result in injuries Warning of hot surface Warning of suspended load 1 1 Safety instructions A supervisor responsible person must be appointed for the ma chine This person must a Completely read and und...

Page 4: ...y a Rühle service technician e Provide personal protective equipment All life cycles phases Wear foot protection Wear hand protection Wear protective clothing Cleaning care maintenance dismantling Wear eye protection Use light breathing mask Care maintenance Wear hearing protection The operator must operate the machine according to the intended use and strictly observe all points listed in the Ope...

Page 5: ...able PC from the bracket and switch it off permanently The machine must be secured against further use The supervisor must arrange for the repair of the non functional safety device by a Rühle service technician Until the corresponding parts have been repaired the supervisor must ensure that the ma chine or parts of the machine are under no circumstances put into op eration The cleaning personnel ...

Page 6: ...swivel range of the drum is therefore strictly prohibited All life cycles phases Work on the cooling unit and cooling system may only be carried out by a refrigeration installer All life cycles phases Staying beneath the lifting aid standard trolley support and reaching into the area of moving parts is strictly pro hibited The standard trolleys provided must be used Maintenance The machine must be...

Page 7: ...ohibited and is considered misuse Operating the machine in explosion hazard areas is prohib ited Handling processing products and materials not belonging to food products is prohibited The lifting aid may be used only for the standard trolleys pro vided and must not be overloaded Lifting of persons is strictly prohibited Connecting several tablet PCs with a machine is prohibited 2 Installation ins...

Page 8: ...must be decommissioned until a damaged power supply line has been repaired Make sure the machine is stable Make sure the machine bases have contact with the setup surface and are then tightened Ensure that the max filling quantity of 400 kg per stand ard trolley is not exceeded 2 2 Workplace description The work area around the machine is at least 0 5 m on all sides for maintenance work it is at l...

Page 9: ... tion of rotation inside the mains plug The power supply to the machine must be fuse pro tected with 32 A secured with an AC DC sensitive ground fault circuit interrupter type B 3 Operating instructions Please refer to the short instructions supplied with your machine for the operation of your Miknetum Follow also the safety instructions in Chapter 1 1 Make sure that you are connected to the right...

Page 10: ...g arm Installation and removal of mixing arm Installation and removal of standard trolley support Installation and removal of protective gearbox cover Transport of machine and machine parts Maintenance work inside the drum Depending on the user programs temperatures down to 25 C may be generated in the drum Take the corre sponding precautions Do not touch the tumbling arm mixing arm with your hand...

Page 11: ... lid and its lock may jump open during unlocking Make sure each time work commences that the outer lid is closed and locked that the lid seal has been inserted correctly by checking at program start whether a pressure loss is indicated on the pressure display if the machine is able to create a vacuum If this is the case the seals have been mounted correctly Otherwise check the seals Please refer t...

Page 12: ...notify the supervisor immediately of any defects on the machine The cleaning staff must use the specified cleaning agents and disinfectants Germ reduction is achieved only by correct cleaning and subse quent disinfection Appropriate material e g brushes rags is required and must be provided for the proper procedures of the above Cleaning products and disinfectants approved for the food prod uct ar...

Page 13: ...rmal water pressure 4 2 Cleaning agents and disinfectants The following cleaning agents and disinfectants must be used Cleaning agents Alkaline cleaning Acidic cleaning P3 topax 12 P3 topax 19 P3 topax 66 P3 topax 56 Disinfectants P3 topax 91 P3 topax 99 Supplier Henkel Hygiene GmbH Bonner Str 117 D 40589 Düsseldorf Tel 49 211 9893 0 Or Cleaning agents Alkaline cleaning Acidic cleaning Somplex F f...

Page 14: ...C from the holder and close it Fold up the holder 5 Service Care maintenance repair Any work related in any way with service may be carried out only by Rühle service technicians and by persons authorised by Rühle in writ ing In this regard a distinction is made between regular care and maintenance and repair The respective qualification certificate must be issued explicitly for the corresponding w...

Page 15: ...te nance or notify Rühle Service Care schedule a Disassemble the machine according to the cleaning instruc tions Check for any parts moving with difficulty material abrasion or other signs of wear and tear b Check hygienic condition and function of lid seals c Check function and firm seating of the closures at the tum bling and mixing arms or blind plugs d Check hygienic condition of the stripper ...

Page 16: ...f Check function of pressure transmitters and temperature sen sors g Inspect the hoses vacuum system h Check radial shaft seals for leak tightness replace otherwise i Read the error memory frequency converter 5 3 Repair and spare parts As a damaged part on a machine is usually damaged due to causes unrelated to the part always carry out a fault diagnosis For this reason contact our Service Hotline...

Page 17: ...isposed of at a recy cling facility 7 Technical documentation 7 1 Technical data Connection voltage 400 V 50 60 Hz 3 phase AC N PE Power consumption 14 6 kW Full load current 27 1 A Back up fuse max 32 A Protection class IP54 Ambient temperature 2 to 40 C Dimensions W x H x D 4667 x 3871 x 4046 mm Machine weight 3100 kg Transport weight 3200 kg Container size 1500 litres Max filling 900 litres Ref...

Page 18: ...in switch In case of deviations contact the manufacturer for a written confirmation of the data If your country requires a ground fault circuit interrupting device as protective measure a ground fault circuit interrupting device type B AC DC sensitive must be used 7 2 Electrical circuit diagram The electrical circuit diagram of your machine is located in the electri cal control cabinet and must be...

Page 19: ... 2009 07 Food processing machinery Basic concepts Part 2 Hygiene requirements DIN EN 60204 1 2007 06 A1 2009 10 Safety of machinery Electrical equipment of machines Part 1 General requirements EC 1935 2004 Regulation on materials and articles intended to come into contact with food Appointed department Reason for the involvement of the ap pointed department Name legal form DGUV Test Prüf u Zertifi...