HeiTel by Xtralis
CamDisc HNVR Product Guide
26419_04
43
Logfile entry
Description
Optional
Error relay
[D&T], Alarmcall
failed: [x], AR:[y]
Alarm connection to receiver with telephone
number / IP address indicated in filed [x] could
not be established. Field [y] indicates the alarm
reason (AR):
Possible values for [y]:
Control input, camera 1 - 10:
01 - 10
Sabotage alarm - general alarm input: 11
Sabotage alarm - enable/disable
status input:
12
Sabotage alarm - sabotage-status
input:
13
General alarm:
17
Panic alarm (Tamper):
24
Device reboot (Power on):
25
Motion alarm, camera 1 - 10:
31 - 40
Video loss, camera 1 - 10:
41 - 50
Alarm released by serial command,
camera 1 - 10:
51 - 60
Camera position authentication,
camera 1 - 10:
71 - 80
Alarm panel triggered alarm camera 1
- 10:
81 - 90
Alarm triggered by picture warning
threshold (disk full) for event recording
camera 1 - 10:
91 - 100
Alarm triggered by picture warning
threshold (disk full) for continuous
recording camera 1 - 10:
101 - 110
Tamper alarm camera 1 - 10:
111 -120
PIR alarm camera 1 - 10:
121 - 130
Tamper alarm (PIR) camera 1 - 10:
131 - 140
IntrusionTrace alarm camera 1 - 10:
141 - 150
no
yes
[D&T], Caller, [x],
[y]
Caller indicates the log in the order of the last
login (0=one, 1=two etc.). Field [x] and field [y]
indicates telephone number / IP address.
yes
no
[D&T], Service Call,
[x]
The device triggered a service call to telephone
number / IP Address in field [x].
no
no
Summary of Contents for HeiTel CamDisc HNVR
Page 1: ...CamDisc HNVR Product Guide February 2017 Document 26419_04 Software Version 4 58 ...
Page 2: ......
Page 6: ...CamDisc HNVR Product Guide HeiTel by Xtralis 6 26419_04 This page is intentionally left blank ...
Page 8: ...CamDisc HNVR Product Guide HeiTel by Xtralis 8 26419_04 This page is intentionally left blank ...
Page 67: ......