Note:
This display will function differently, based on the software
revision contained in the weld control unit. Refer to the
Operator’s Manual provided with the weld control for more
complete information on the stepper operation and
programming.:
The stepper displays weld heat as secondary current if the last
weld function executed used constant current compensation, or
as % heat if the weld function used automatic voltage
compensation.
<Y^UQbCdU``UbCdQdec4UcSbY`dY_^
The Linear Stepper Status display shows the following
information about the stepper:
Boost: + 02%
This is the heat that will be provided to the next weld:
+02% is the heat added by the linear stepper, based
on the step profile, to the weld functions.
Total Welds= 00000
This field is the total number of welds initiated since
the stepper was last reset.
Step #01
This field is how far the stepper has progressed
through the step profile (the number of steps is
determined by the weld control). You can advance
the stepper by changing this value: press the
O
key, enter a number and press
-
. (Or press
O
twice.)
Step Count=0000
This field shows the number of welds initiated during
this step. You can also advance the stepper to
another step by changing this value: Press
O
,
enter a number and press
-
. (Or press
O
twice.)
Total Welds: 00000
This field is the total number of welds initiated since
the stepper was last reset.