127
6196-2220
+CCED – Automatic RxLev indication
Description:
The CCED command has been extended to indicate the received signal strength indica-
tion (rssi) of the main cell.The command principle has not changed.
Syntax:
AT+CCED=<mode>[, <requested dump>]
Defined values:
<mode>
0:
One shot requested
1:
Automatic shots requested
2:
Stop automatic shots
<requested dump>
8:
Main cell RSSI indications (RxLev) from 0 to 31
The response will be a +CSQ response and not a +CCED response.
The 07.07 format for +CSQ is respected.The <ber> is not evaluated
by this command, so the <ber> value will always be 99.
+CSQ :<rssi>, 99
OK
This +CSQ response, when automatic shots are selected, is sent every time the <rssi>
measured by the product changes. Automatic shots are supported in idle mode and dur-
ing communication. Combination (addition of the values) of the requested dump (1,2,4,8)
are supported but the activation or deactivation of this flow (8) does not affect the other
flows. Both +CCED and +CSQ responses may then be generated. If the <requested
dump> parameter is absent, the last +CCED command parameter (or 15 by default) will
be used.