93
6196-2220
Data commands
+CBST – Bearer type selection
Description:
This command applies to both outgoing and incoming data calls, but in a different way.
For an outgoing call, the two parameters (e.g. <speed> and <ce>) apply, whereas for an
incoming call, only the <ce> parameter applies.
NOTE 1:
For incoming calls, if <ce> is set to T only and the network offers NT only or
vice versa, then the call is released.
NOTE 2:
The former values of 100 and 101 for <ce> are retained for compatibility pur-
poses but should no longer be used, values 2 and 3 should be used instead.
Syntax:
AT+CBST= <speed>, <name>, <ce>
Command example
Possible responses
Note
AT+CBST=?
+CBST:
Test command
(0-8,12,14,65,66,68,
70,71,75),(0),(0-3)
OK
AT+CBST=7,0,1
OK
Ask for a bearer, result:
Bearer supported
AT+CBST?
+CBST:7,0,1
Current values
OK
AT+CBST=81,0,0
+CME ERROR: 4
Ask for a bearer, result:
Bearer not supported
Defined values:
No data compression is provided and only asynchronous modem is supported
(<name> = 0).
Summary of Contents for GD-01 TCP