No
�
Fault
Possible cause
Remedial measur
es
Remark
4
The locking le
ver can no
longer be actuated, is stuck or damaged.
Incorr
ect handling of the
no
zzle (e.g. b
y dr
opping)
Release the locking le
ver
using the scr
ewdriv
er
-
Replace the locking le
ver
.
See
5
Data inter
face no longer
sends any data or is
damaged
Incorr
ect handling of the
no
zzle (e.g. b
y dr
opping)
Replace data inter
face
See
Send the fueling no
zzle to
WEH for maintenance
-
6
Swiv
el joint stuck or stiff
Incorr
ect handling of the
no
zzle (i.e. dr
opping it)
Send the fueling no
zzle to
WEH for maintenance
-
Def
ectiv
e components
7
Leakage in the fueling no
zzle
or in the media inlet
Def
ectiv
e sealing
components
Send the fueling no
zzle to
WEH for maintenance
-
Fitting on the media inlet
‘B1’ leaking
8
Label is no longer legible, or is missing
Fueling no
zzle has been
exposed to the weather
without pr
otection
Replace label
See
The adhesiv
e on the label
has dissolv
ed
In case of pr
oblems, please contact WEH or y
our r
esponsible distributor
.
MD-10013-L51-R1.6.0-03