TK17 H
2
with ENR
Characteristics
Basic version
Nominal bore (DN)
fuelling nozzle
4 mm
Nominal bore (DN)
purging line
4 mm
Pressure range
fueling nozzle
PN = 35 MPa | PS = 45 MPa (High-Flow)
PN = 35 MPa | PS = 49 MPa
PN = 70 MPa | PS = 87.5 MPa
Maximum allowable
operating pressure
(when not connected)*
PS = 50 MPa (valid only for TK17 H
2
70 MPa)
Flow rate during
purging**
500 Nl/h at max. 12 bar purging pressure
Medium for purging**
Nitrogen
Media temperature range
fueling nozzle
-40 °C to +85 °C
Ambient temperature
range fueling nozzle
-40 °C to +85 °C
Media temperature range
purging medium**
-20 °C to +85 °C
Part materials
Wear-resistant stainless steel, corrosion-resistant surfaces
Sealing materials
Hydrogen-resistant
Nozzle type
Type C acc. to SAE J2600:2015 and previous resp.
ISO 17268:2012 and previous
Design
With plastic thermal protection, cold protection, hand grip with
magnet, exchangeable data interface acc. to SAE TIR J2799 and
integrated purging line
Weight
Approx. 2.4 kg
Conformities /
Tests /
Approvals
Fueling nozzle:
- Tests acc. to SAE J2600:2002
IR data interface:
- SAE TIR J2799
- ATEX, NEC, KTL or CCC
* Note: If the fueling nozzle is loaded with pressures > 50 MPa when not connected,
leackages may occur that are higher than that defined by international standards.
** The efficiency of the purging line has been successfully tested in compliance with the
freezing test 7.26 from ISO 17268
MD-10013-L51-R1.6.0-03
Page 15
Operating instructions
AE
Summary of Contents for TK17 H2
Page 2: ......