136
HPSA-7100-R Series Installation and User Manual
P/N P01-04946-C
TABLE A.1
AMB Trouble State Jumpers and Connections
Trouble
Output
Trouble Output
Jumper Selection
Contact Pairs
(J2 Pins)
Normal State
Trouble State
AC
J7 2-3
J7 1-2
C - NO
a
1 to 2
C - NC
b
1 to 2
a.
NO
= Normally Open
b.
NC
= Normally Closed
Open
Closed
Closed
Open
No Battery
J8 2-3
J8 1-2
C - NO 3 to 4
C - NC 3 to 4
Open
Closed
Closed
Open
Low Battery
J9 2-3
J9 1-2
C - NO 5 to 6
C - NC 5 to 6
Open
Closed
Closed
Open
Door Open
J10 2-3
J10 1-2
C - NO 7 to 8
C - NC 7 to 8
Open
Closed
Closed
Open
Amps
J11 2-3
J11 1-2
C - NO 9 to 10
C - NC 9 to 10
Open
Closed
Closed
Open
Drivers
J12 2-3
J12 1-2
C - NO 11 to 12
C - NC 11 to 12
Open
Closed
Closed
Open
Summary of Contents for HPSA-7100-R Series
Page 2: ...This page intentionally left blank...
Page 10: ...viii HPSA 7100 R Series Installation and User Manual P N P01 04946 Rev C...
Page 16: ...xiv HPSA 7100 R Series Installation and User Manual P N P01 04946 Rev C...
Page 20: ...xviii HPSA 7100 R Series Installation and User Manual P N P01 04946 Rev C...
Page 22: ...xx HPSA 7100 R Series Installation and User Manual P N P01 04946 Rev C...
Page 26: ...Preface xxiv HPSA 7100 R Series Installation and User Manual P N P01 04946 Rev C...
Page 33: ...HPSA 7100 R Series Installation and User Manual 7 P N P01 04946 Rev C System Components...
Page 34: ...Introduction 8 HPSA 7100 R Series Installation and User Manual P N P01 04946 Rev C...
Page 58: ...Installing the Cabinet 32 HPSA 7100 R Series Installation and User Manual P N P01 04946 Rev C...
Page 174: ...148 HPSA 7100 R Series Installation and User Manual P N P01 04946 Rev C...
Page 178: ......