Notice
Date
Page
01201055
INSTRUCTION
HANDBOOK
Drain connection
The machine's exhaust sleeve outside diameter is of 75 mm (3"). Depending of your installa-
tion, it might be fit on the left or right side of the machine.
Adapt and connect the rubber bend (H) to the machine's exhaust sleeve and to the wasted
waters collector (rubber bend supplied with one collar in the machine).
Avoid acute bends or folds which might prevent water from flowing out.
The end of the pipe has to open in the air, at minimum 25 mm (1") on top of a ground siphon,
drain pipe or another similar dispositive.
The waste water collector diameter 150 mm (6") (manufactured by customer) should have a 3
cm/m (3 %) slope and resist to a temperature of 90 °C (194 °F). It should be connected to the
waste water general network in accordance with local codes and regulations.
9. Installation
0102
10
9
D0624