Notice
Date
Page
01201055
INSTRUCTION
HANDBOOK
0999
51
11
11. Machine
operation
Zero calibration
(for machines with weighing equipment installed only)
4796
SERVICE PROGRAM
MAKE A CHOICE :
RESET SCALE TO ZERO
RESET TARE TO ZERO
TARE SCALE
SET TARE TO A CERTAIN VALUE
READ TARE VALUE
CALIBRATE THE SCALE
RESET SCALE TO ZERO
RESET TARE TO ZERO
TARE SCALE
SET TARE TO A CERTAIN VALUE
READ TARE VALUE
READ VERSION NUMBER
EXIT
CALIBRATE THE SCALE
ZERO CALIBRATION
4797
PRESS SELECT FOR
ZERO CALIBRATION
SCALE ADJUSTMENTS
ZERO CALIBRATION
4798
DONE !
PRESS SELECT
SCALE ADJUSTMENTS
ZERO CALIBRATION
If you wish to calibrate zero for
the weighing equipment :
This screen shows you have
calibrated zero.
Please note :
The machine must be unladen during this calibration,
i.e. no water or wash load in the drum.
Zero calibration
The "Zero calibration" function is used to increase the
accuracy of the weighing equipment. This should be
done once a month.
If this calibration has not succeeded you will see an
error message equivalent to: "FAILED. PRESS
SELECT" on the display.
For troubleshooting, see the section "Fault-finding,
weighing equipment" in the machine manual.
Press SELECT.
Press
ò
six times to
highlight "ZERO
CALIBRATIONN".
Press SELECT.
Press SELECT.