HANDBOOK
Check-out
Before leaving, put the appliance into operation and allow to run a
complete cycle. Watch to ensure that all burner system components
function correctly.
IMPORTANT
Tightness test after installation
The gas leak test is performed as follows :
1/ Paint pipe joints, pilot gas tubing connections and inspect outlets with
rich soap and water solution ; do not use an aggressive soap.
2/ Put the machine into service. Bubbles indicate a gas leak.
3/ Eliminate this leak.
NOTE : After all intervention, re-seal (red varnish) the following adjustment
organs :
- regulator of pressure
In case of changing of gas, the stick for the adjustment has to be modified.
9. Installation
0800
21