Notice
Date
Page
01201055
INSTRUCTION
HANDBOOK
0999
42
11
11. Machine
operation
Scale adjustments
(for machines with weighing equipment installed only)
4777
SERVICE PROGRAM
MAKE A CHOICE :
SERVICE PROGRAM
CLEAR COUNTER
CLEAR SERVICE COUNTER
CLEAR WASH COUNTER IN PCS
CLEAR WASH COUNTER IN MEMORY CARD
SCALE ADJUSTMENTS
SERVICE PROGRAM
CLEAR SERVICE COUNTER
CLEAR WASH COUNTER IN PCS
CLEAR WASH COUNTER IN MEMORY CARD
SCALE ADJUSTMENTS
EXIT
Press
ò
repeatedly until
SCALE ADJUSTMENTS is
highlighted.
Press SELECT.
When you have finished :
Press
ò
repeatedly until EXIT
is highlighted.
Scale adjustments
The following functions are accessed via the SCALE
ADJUSTMENTS menu :
Reset scale to zero (see section "Reset scale to
zero")
Used to make the weighing equipment display 0
when the machine has no load in it.
Reset tare to zero (see section "Reset tare to zero")
Used to clear a stored tare parameter.
Tare scale (see section "Tare scale")
Used to reset the weighing equipment so that a
weight such as a container will not be included when
calculating net weight.
Set tare to a certain value (see section "Set tare to a
certain value")
Used to enter a value for the tare parameter, a
weight in hectograms.
Read tare value (see section "Read tare value")
Used to check the value currently stored as the tare
parameter.
Calibrate the scale (see section "Calibrate the
scale")
This function is used only on installation of a new
scale unit.
Zero calibration (see section "Zero calibration")
Used to increase the accuracy of the weighing
equipment.
Read version number (see section "Read version
number")
This is where you find the version number of the
weighing equipment.
If the weighing equipment is not connected, the error
message "WEIGHING EQUIPMENT NOT
CONNECTED" will be displayed. Connect the
weighing equipment and try again. If necessary, see
the section "Fault-finding, weighing equipment" in
the machine manual.
Press SELECT.