![Wascomat WS3 230 H Instruction Handbook Manual Download Page 22](http://html1.mh-extra.com/html/wascomat/ws3-230-h/ws3-230-h_instruction-handbook-manual_873603022.webp)
Notice
Date
Page
01201055
INSTRUCTION
HANDBOOK
Washer extractor type 470 standard
Diagram no. 07100085
0102
6
8
8.Technical
characteristics
Heating
Gas
Electric
Steam Thermic fluid
Characteristics
Ø cage
--------------------------- 770 mm (30.31")--------------------
Cage length
----------------------------- 1040 mm (41") -------------------
Cage volume
----------------------- 467 dm³ (467 l) --------------------
Specific load 1/11
--------------------------- 42.5 kg (94 lb)-----------------------
(dry linen, ISO 9398-4)
Opening cage doors (L x H) ---------------- 2x450 x 400 mm (17.71x15.74")-----------
Opening drum door (L x H) ------------------ 935 x 527 mm (36.81x20.74") ------------
Floor area
------------------------ 1.52 m² (16.36 sq. ft) ----------------
Net weight
--------------------------- 870 daN (1919 lb)-----------------
Weight loaded (high level)
--------------------------- 1272 daN (2805 lb)----------------
Water, washing, low level
xx l
xx l
xx l
xx l
Water, washing, high level
xx l
xx l
xx l
xx l
Dynamic stress
--------------------- F = 275 daN (606 lb)-------------------
Transmitted floor load
----------------------- 830 daN (1830 lb)--------------------
Spin efficiency
---------------------------------- 350 G ------------------------
Max. unbalance
--------------------------- 5.5 kg (12.13 lb)--------------------
(L) Main switch to connect main cable
(M) Electric cable (section)
4x2.5 mm²
4x25 mm²
4x2.5 mm²
4x2.5 mm²
(N) or (N') Stuffing box for main cable
Supply voltage
-------------------------380 / 415 V 3+E ~ 50/60 Hz------------
Installed electric power
5.8 kW
42 kW
5.8 kW
5.8 kW
Installed heating power
40 kW
36 kW
-
-
Electrical consumption for a normal cycle
* 1.5 kWh/h
11 kWh/h
1.2 kWh/h
1.2 kWh/h
Heat loss
-------------------3 % of installed heating power--------------
(G) Steam inlet
DN 20 (3/4" BSP)
- Maximum supply pressure
600 kPa (87 psi)
- Steam instantaneous flow rate at 600 kPa
x kg/h
- Steam consumption for a normal cycle*
24.5 kg/h at 600 kPa (87 psi)
(D) Hot water connection / flow
DN 20 (3/4" BSP) - 70 l/min at 250 kPA (36 psi)
(E) Cold hard water connection / flow
DN 20 (3/4" BSP) - 70 l/min at 250 kPA (36 psi)
(F) Cold soft water connection / flow
(option)
DN 20 (3/4" BSP) - 70 l/min at 250 kPA (36 psi)
Water supply minimum pressure
--------------------------- 50 kPa (7.25 psi)------------------
Water supply maximum pressure
--------------------------- 300 kPa (43.5 psi)----------------
Water consumption for a normal cycle
*
638 l
610 l
610 l
610 l
Water consumption for an ECO cycle
**
558 l
530 l
530 l
530 l
(K) Liquid detergents inlet
(H1 or H3 or H5) Drain connection
--------------------------- Ø 75 mm (3")----------------------
(H2 or H4 or H6) Double drain connection
--------------------------- Ø 75 mm (3")----------------------
Maximum drain flow rate
xx l/min
xx l/min
xx l/min
xx l/min
(I) Waste water collector
------------------------ DN 150 mm (6" BSP)----------------
(3 cm/m (3 %) minimum slope)
(J) Air vent hole
------------------------ Ø 60 mm (2.36 ") ---------------------
(N') Thermic fluid inlet
DN 15 (1/2" BSP)
(G) Thermic fluid return
DN 15 (1/2" BSP)
- Maximum supply pressure
xxx kPa
- Installed calorific power
xxx kcal
- Average calorific consumption
xxx kcal/h
- Inner volume thermic fluid
xx l
Gas inlet
DN 20 (3/4" BSP)
Combustion products evacuation
Ø 125 mm (5")
* normal cycle : prewash 3 min at 35 °C, drain. 2 min, main wash 4 min at 65 °C, drain 2 min, rinse 2 min, extract. 2 min, rinse 2 min,
extract 2 min, rinse 2 min, extrac. 10 min (cold water supply at 15 °C).
** ECO cycle : normal cycle with rinse 5 l/kg instead of 6 l/kg dry linen.