11. Machine
operation
0999
1
11
Emergency stop
The emergency stop must be unblocked, if not the machine will not work (to unblock, turn the
red button to the right).
If the machine for some reason has to be stopped, abnormal or dangerous running, press
emergency stop button.
Nota : it is necessary to wait for 30 seconds before resetting after any action on the emergency
stop.
Release the emergency stop, by turning it clockwise only after checking what motivated this
stop.
D0543
D0544
Gas exchanger
Two indicators are situated on the top of the
gas exchanger.
White indicator (1) light = "gas heating
On".
Yellow indicator (2) light = "ignition gas
burner fault indicator".
The yellow indicator remains on if a fault
occurs when the gas burner ignites, the gas
heating does off and the machine stops
functioning. Verify the working of the gas
exchanger. If la fault remains, consult your
after-sales service.
D0697
1
2
Auxiliary controls