8.Technical
characteristics
Heating
Gas
Electric
Steam Thermic fluid
Characteristics
Ø cage
--------------------- 770 mm (30.31") -------------------
Cage length
----------------------- 1550 mm (59") -------------------
Cage volume
---------------------- 668 dm³ (668 l) ---------------------
Specific load 1/11
----------------------- 61 kg (134 lb) ----------------------
(dry linen, ISO 9398-4)
Opening cage doors (L x H) -------------- 2x600 x 400 mm (23.62x15.74") -------------
Opening drum door (L x H) --------------- 2x616 x 525 mm (24.25x20.66") -------------
Floor area
------------------ 2 m² (21.53 sq. ft) ------------------
Net weight
------------------- 940 daN (2073 lb) -------------------
Weight loaded (high level)
------------------ 1589 daN (3504 lb) ------------------
Water, washing, low level
xx l
xx l
xx l
xx l
Water, washing, high level
xx l
xx l
xx l
xx l
Dynamic stress
------------------ F = 466 daN (1028 lb) ----------------
Transmitted floor load
---------------------- 811 daN (1789 lb) ------------------
Spin efficiency
----------------------------- 350 G ---------------------------
Max. unbalance
------------------------ 8 kg (17.65 lb) ------------------
(L) Main switch to connect main cable
(M) Electric cable (section)
4x2.5 mm²
4x35 mm²
4x2.5 mm²
4x2.5 mm²
(N) or (N') Stuffing box for main cable
Supply voltage
-------------------------380 / 415 V 3+E ~ 50/60 Hz------------
Installed electric power
7.8 kW
61.5 kW
7.8 kW
7.8 kW
Installed heating power
40 kW
54 kW
-
-
Electrical consumption for a normal cycle
* 2 kWh/h
23 kWh/h
2 kWh/h
2 kWh/h
Heat loss
-------------------3 % of installed heating power--------------
(G) Steam inlet
DN 20 (3/4" BSP)
- Maximum supply pressure
600 kPa (87 psi)
- Steam instantaneous flow rate at 600 kPa
x kg/h
- Steam consumption for a normal cycle*
24.5 kg/h at 600 kPa (87 psi)
(D) Hot water connection / flow
DN 20 (3/4" BSP) - 70 l/min at 250 kPA (36 psi)
(E) Cold hard water connection / flow
DN 20 (3/4" BSP) - 70 l/min at 250 kPA (36 psi)
(F) Cold soft water connection / flow
(option)
DN 20 (3/4" BSP) - 70 l/min at 250 kPA (36 psi)
Water supply minimum pressure
---------------------- 50 kPa (7.25 psi) -------------------
Water supply maximum pressure
--------------------- 300 kPa (43.5 psi) ------------------
Water consumption for a normal cycle
*
977 l
977 l
977 l
977 l
Water consumption for an ECO cycle
**
782 l
782 l
782 l
782 l
(K) Liquid detergents inlet
(H1 or H3 or H5) Drain connection
------------------------- Ø 75 mm (3") ---------------------
(H2 or H4 or H6) Double drain connection
------------------------- Ø 75 mm (3") ---------------------
Maximum drain flow rate
xx l/min
xx l/min
xx l/min
xx l/min
(I) Waste water collector
--------------------- DN 150 mm (6" BSP) --------------
(3 cm/m (3 %) minimum slope)
(J) Air vent hole
------------------------ Ø 60 mm (2.36") ------------------
(N') Thermic fluid inlet
DN 15 (1/2" BSP)
(G) Thermic fluid return
DN 15 (1/2" BSP)
- Maximum supply pressure
xxx kPa
- Installed calorific power
xxx kcal
- Average calorific consumption
xxx kcal/h
- Inner volume thermic fluid
xx l
Gas inlet
DN 20 (3/4" BSP)
Combustion products evacuation
Ø 125 mm (5")
(O) Barrier partition
(provided by customer)
(P) Frame
50x100 mm (provided by customer)
(R) Foam joint
Washer extractor type 670 barrier
Diagram no. 07100088
* normal cycle : prewash 3 min at 35 °C, drain. 2 min, main wash 4 min at 65 °C, drain 2 min, rinse 2 min, extract. 2 min, rinse 2 min,
extract 2 min, rinse 2 min, extrac. 10 min (cold water supply at 15 °C).
** ECO cycle : normal cycle with rinse 5 l/kg instead of 6 l/kg dry linen.