Notice
Date
Page
01201055
INSTRUCTION
HANDBOOK
9. Installation
0800
16
9
D0291
The gas exchanger is adjusted at the plant to be suitable for the kind of gas specified on the
order. If you have to supply your machine with gas in a family different from the gas for which
your machine was adjusted, proceed as follows.
Testing pressures
According to the EN 437 standard, the values of the testing pressures mentioned in our various
documents are values for static pressure taken at the gas inlet connection of the machine ; the
heating of the machine being on.
Changing to a gas in the same
family (type H or L)
•
Change the 3 injectors with joints and if
necessary, adjust the air flow (see tables of
correspondences).
Changing to a gas in a different
family (from type H or L to
butane or propane)
•
Change the 3 injectors with joints (see tables
of correspondences)
•
Unscrews the fixing screws (V) and remove
the adjusting head (J) as well as its cork (T),
keep these parts in case a change would by
necessary.
•
Replace it by the cork (L) and the plate (P).
•
Screw the two screws and block.
•
Adjust the air flow (see tables of
correspondences).
Changing a gas from one family
to another (from butane or
propane to type H or L)
•
Change the 3 injectors with joints (see tables of correspondences)
•
Unscrews the fixing screws (V) and remove the plate (P) as well as the cork (L), keep these
parts in case a change would by necessary.
•
Set the cork (T) and the adjustment head (J).
•
Screw the two screws and block.
•
Adjust the air flow (see tables of correspondences).