Operating manual Universal Control Unit for Powder Spray Guns EPG-SPRINT XE
7 Operation
Order number 2354913 | Edition 10/2022
41
EPG
SPRINT X
0
%
100
%
10
20
30
40
50
60
70
80
90
Ø
12
10
11
9
8
m /h
2.0
3.0
0.5
0.3
0.1
1.5
3
5.5
4.5
3.5
2.5
Tri
P_01752
19
24
33
2. The powder quantity can now be set using the universal control dial (24) between 0 –
100% with a resolution of 1%. The value is shown in the LED display (19).
When the control unit is in the ready position, the circular light strip (33) shows the set point
as a dot and when powder feed is switched on it shows the actual value as a bar. The powder
quantity setting as a % refers to the percentage distribution of the different air types.
Example:
75% powder quantity means that 75% of the total air volume is supplied to the feed air and
25% to the dosing air. The greater the proportion of feed air, the greater the powder
quantity for the specified total air volume.
7.6.3 Setting the Additional Air (Atomizing/Ionizing/Tribo Air Volume)
EPG
SPRINT X
0
%
100
%
10
20
30
40
50
60
70
80
90
Ø
12
10
11
9
8
m /h
2.0
3.0
0.5
0.3
0.1
1.5
3
5.5
4.5
3.5
2.5
Tri
P_05021
23
21
1. Press [Additional air] push button (21) to set the additional air volume. Yellow LED (23)
indicates that the additional air is selected.