Operating manual Universal Control Unit for Powder Spray Guns EPG-SPRINT XE
5 Description
Order number 2354913 | Edition 10/2022
23
– Display range: 0 – 100%
– Resolution: 3.33%
– Single LED display: Set point (high voltage and powder are deactivated)
– Bar display: Actual value (high voltage and powder are activated)
34 Illuminated display [Total air volume]
– Lights up green
– Display range: 2 – 6 m
3
/h
– Resolution: 0.2 – 0.5 m
3
/h
– Single LED display: Set point (high voltage and powder are deactivated)
– Bar display: Actual value (high voltage and powder are activated)
35 Illuminated display: [Atomizing, ionizing and Tribo air volume]
– Lights up green
– Display range: 0.1 – 4 m
3
/h
– Resolution: 0.1 – 1.0 m
3
/h
– Single LED display: Set point (high voltage and powder are deactivated)
– Bar display: Actual value (high voltage and powder are activated)
36 Push button [Powder quantity]
– To activate the function, the powder quantity is set with control dial 24 and is indicated
in LED display 19.
– Adjusting range: 1 – 100%
– Resolution: 1%
37 LED display [Powder quantity]
– Lights up yellow, when the powder quantity is selected
5.4.2 Connections on the Rear Side
Type /
Typ:
Serial No.:
Serie Nr.:
Voltage:
Spannung:
Line Power:
Eingangsleistung:
Prot. Class:
Schutzart:
EPG-SPRINT XE
90-250 VAC 47-63 Hz
max. 110 W
IP64
CH 9450 Altstätten
Wagner International AG
Made in Switzerland
PTB 12 ATEX 5001
II 3(2)D
Tested /
Geprüft
: EN50050-2, EN50177
0102
F1 Fuse F2
Sicherung
2 AT
250VAC
2 AT
250VAC
(slow blow)
Hauptschalter
Main switch
Spraygun
Sprühpistole
Remote
Fernsteuerung
Ausgang zur Pistole
Output to gun
I max. 0,9 A
U max. 22 Vpp
Dosage air
Dosierluft
Feeding air
Förderluft
Atomizing air
Zerstäuberluft
Mains
power
input
Netz-
eingang
Mains
output
vibrator
Netz-
ausgang
Rüttler
6.....8 bar
87..116 psi
Clean and
dry air
Saubere und
trockene Luft
6.5.2 (ISO 8573.1)
Do NOT disconnect when energized!
NICHT unter Spannung trennen!
I
O
Air input
Lufteingang
For operation all ports must be fitted
with a plug or the protection cap.
Für den Betrieb in der Zone 22
müssen alle Anschlüsse mit Stecker
oder Schutzkappe versehen sein.
Overvoltage Category II
and pollution Degree 2
EPG-Sprint XE
FM approved for CL II, Div 2, Grps E, F, &G
Ambient temp range 5C to 40C T5
In accordance with control document: 2309729
Acceptable equipment combination
see operator manual
Zulässige Gerätekombination
siehe Betriebsanleitung
Year of manufacture:
Baujahr :
2
1
10
13
4
3
5
9
8
7
13
6
11
12
P_02653
14
1 Mains supply switch
– 0 = The control unit is deactivated