Operating manual Universal Control Unit for Powder Spray Guns EPG-SPRINT XE
7 Operation
40
Order number 2354913 | Edition 10/2022
EPG
SPRINT X
0
%
100
%
10
20
30
40
50
60
70
80
90
Ø
12
10
11
9
8
m /h
2.0
3.0
0.5
0.3
0.1
1.5
3
5.5
4.5
3.5
2.5
Tri
P_01751
19
24
34
2. The total air volume can now be set using the universal control dial (24) between 1 –
6 m
3
/h with a resolution of 0.05 m
3
/h. The value is shown in the LED display (19).
To the right of the [Total air volume] push button (20) is the [Total air] bar graph display (34).
When the control unit is in the ready position, this light strip shows the set point as a dot and
when powder feed is switched on it shows the actual value as a bar.
To the right of the bar graph is the scale for the total air volume. To the left of the bar graph
is another scale indicating the hose diameter. This scale shows the correlation between the
total air volume and the inner hose diameter (see operating manuals for the powder
injectors PI-F1 and HiCoat ED-Pump-F). The inner hose diameter is printed on the powder
hose.
Example:
Inner hose diameter 11 mm
Total air 4.5 m
3
/h
The total air volume can be set between 1 – 6 m
3
/h as described above. If this value is further
reduced from a value of 1 m
3
/h, the word [off] appears in the LED display (19) to signal that
the total air supply is deactivated. The total air supply is not therefore activated when the
powder feed is switched on.
7.6.2 Setting the Powder Feed Quantity
EPG
SPRINT X
0
%
100
%
10
20
30
40
50
60
70
80
90
Ø
12
10
11
9
8
m /h
2.0
3.0
0.5
0.3
0.1
1.5
3
5.5
4.5
3.5
2.5
Tri
P_05020
37
36
1. Press the [Powder quantity] push button (36) to adjust the powder quantity. Yellow LED
(37) indicates that the powder quantity is selected.