Operating manual Universal Control Unit for Powder Spray Guns EPG-SPRINT XE
7 Operation
Order number 2354913 | Edition 10/2022
49
EPG
SPRINT X
0
%
100
%
10
20
30
40
50
60
70
80
90
Ø
12
10
11
9
8
m /h
2.0
3.0
0.5
0.3
0.1
1.5
3
5.5
4.5
3.5
2.5
Tri
P_01769
36
37
19
24
33
If no powder is fed at 0%:
1. Press [Powder quantity] push button (36) for around 2 seconds. The [Powder quantity]
LED (37) flashes rapidly, the [Powder quantity display] (33) flashes. The current value of
the feed air is shown in the LED display 19 (e.g., 1.00 means 1.00 Nm
3
/h). The factory
setting is set to 0.00 Nm
3
/h.
2. Turn universal control dial (24) until just a small amount of powder is fed.
3. To save, hold down the [Powder quantity] push button (36).
ð
The LED display (19) flashes.
4. To discard the set value, press any button briefly.
ð
The value that was originally set is reloaded.
Info
The starting output value is set to 0.00 at the factory.
If the set value is changed, the coating parameters also change, as altering the value
alters the feed air (see diagram).
Example: Total air = 4.00 Nm
3
/h
Starting output 0.00
0.50
1.00
4.50
4.00
3.50
3.00
2.00
1.50
2.50
10
20
30
40
50
60
70
80
100
90
0
P_05032
DL
% P
FL
Nm
3
/h