Operating manual Universal Control Unit for Powder Spray Guns EPG-SPRINT XE
5 Description
Order number 2354913 | Edition 10/2022
21
4 Display [Corona gun]
– Lights up when a Corona gun is connected and selected
5 Push button, recipe for [Surface parts]
6 Push button, recipe for [Second coating]
7 Push button, recipe for [Profile parts]
8 Push button, recipe for [Double-click]
– To access the recipe, press the trigger lever on the spray gun twice in quick succession
and hold it down
9 LED display, recipe for [Surface parts]
– Lights up green when the recipe for [Surface parts] is selected
10 LED display, recipe for [Second coating]
– Lights up green when the recipe for [Second coating] is selected
11 LED display, recipe for [Profile parts]
– Lights up green when the recipe for [Profile parts] is selected
12 LED display, recipe for [Double-click]
– Lights up green, when the recipe for [Double-click] is selected
13 LED display [Fault]
– Lights up, when there is a fault on the device
14 LED display [Automatic gun]
– Lights up, when an automatic gun is connected
15 Push button [Standby]
– To switch into standby mode
– High voltage and powder feed cannot be activated in this mode
– To reactivate normal mode, press the button again
16 LED display [Standby]
– Lights up when the device is in standby mode
17 Push button [Flushing]
– To activate the injector and the hose flushing
18 LED display [Flushing]
– Lights up blue, when the flush function is activated
19 LED display, 7 segments, three-digit number
– Indicates the exact value depending on the activated function:
[Total air volume]; [atomizing, ionizing and Tribo air]; [additional recipes]; [high-voltage
current]; [current limitation]; [powder quantity]
– Display showing error number in the event of warnings and malfunctions
20 Push button [Total air volume]
– To activate the function, the value is precisely adjusted with control dial 24 and is
indicated in LED display 19
– Adjusting range: 1 – 6 m
3
/h
– Resolution: 0.05 m
3
/h
21 Push button [Atomizing, ionizing and Tribo air]
– To activate the function, the value is precisely adjusted with control dial 24 and is
indicated in LED display 19