Operating manual Universal Control Unit for Powder Spray Guns EPG-SPRINT XE
5 Description
24
Order number 2354913 | Edition 10/2022
– I = The control unit is activated
2 Primary fuse (2 pieces)
– 2 ampere, slow-acting
3 Mains input terminal
– Universal input: 90 VAC – 250 VAC
4 Mains output terminal
– Connected for vibrator motor
5 Knurled nut
– To connect the signal ground
6 Compressed air inlet
– Pressure range: 0.6 – 0.8 MPa; 6 – 8 bar; 87 – 116 psi
– Air volume: maximum 15 m
3
/h
– Connection hose diameter 8 mm; 0.315 inch
7 Compressed air outlet for additional air
– With a Corona gun: Atomizing air
– With a Tribo gun: Tribo air
8 Compressed air outlet for dosing air
– For the powder injector
9 Compressed air outlet for feed air
– For the powder injector
10 Gun connection
– To connect a Corona or Tribo gun
11 Remote interface (remote control)
– Start/Stop command of external controller (master controller) for automatic guns
– For wiring, see service manual EPG-SPRINT XE
12 Cover of the service connection
– For WAGNER service personnel only!
13 Fastenings
– For screwing to the rack
14 FM identification
5.5 ACCESSORIES
Only the accessories listed in Chapter Accessories [
64] of this operating manual may be
connected to the EPG-SPRINT XE control unit.