Operating manual Universal Control Unit for Powder Spray Guns EPG-SPRINT XE
16 Appendix Device Configuration
Order number 2354913 | Edition 10/2022
75
Parameter
Value
Description
C16
External recipe selection
(Pulse controller using
remote control bush)
OFF
(factory setting)
The recipe is selected using 4 different
pulse lengths to select recipes 1 – 4.
This setting is compatible with the master
controller.
ON
The recipe is selected by using an ex-
tended pulse/pause protocol to select all
50 recipes and call up the flush function.
This setting should be used if control by a
programmable logic controller (PLC) is the
same as with a Profi Tech Sprint system.
For protocol, see service instructions for
EPG-SPRINT XE.
C17
Powder discharge
Increase in powder discharge
by activating the feed and at-
omizing air in parallel. Both
these airs must be combined
externally by a Y-piece and
supplied to the injector's feed
air connection. The additional
volume differs depending on
injector type. The atomizing
and Tribo air is no longer
available to the spray gun and
must be obtained from a dif-
ferent source.
OFF
(factory setting)
Standard setting for separate hosing for
feed, dosing and atomizing air.
ON
The feed air and atomizing air outputs are
combined for a larger feed air quantity
(higher powder discharge quantity).
Attention: The Tribo and atomizing air is
no longer available.
C18
Display luminance: The dis-
play luminance can be set to
one of three levels.
0
Full display luminance (default setting)
1
Medium luminance (reduced brightness)
2
Minimum luminance (brightness greatly
reduced)
C19
Deletion of created recipes
NO
(factory setting)
No action.
res
All recipes are reset to the delivery condi-
tion if [res] is saved with button (25).
C20
Reset device to delivery condi-
tion
NO
(factory setting)
No action.
res
All settings except recipes are reset to the
delivery condition if [res] is saved with but-
ton (25).
C21
Vibrator motor controller af-
ter-run
10 s
(factory setting)
Vibrator motor has an after-run time of 10
seconds.
OFF
Vibrator motor is not controlled; always
off.
ON
Vibrator motor is always switched on.
1 s - 240 s
Vibrator motor is switched on with the
manual gun's trigger lever and runs for X
seconds after; can be set from 1 second to
240 seconds.