wc_tx003570gb_FM10.fm
44
Mobile Generator
Lifting and Transporting
Continued from the previous page.
5. If the brakes did not function, check the voltage of the breakaway battery.
To do so:
a. Remove the cover of the battery box.
b. Remove the wires connected to the breakaway battery
(d)
.
c. Measure the voltage. If 12–14 VDC is not measured, replace or recharge the
breakaway battery.
6. If 12–14 VDC was measured but the brakes did not function, there is a wiring or
mechanical fault with the brakes. Repair any faults before towing.
7. If the brakes function properly:
a. Reconnect the wires to the breakaway battery.
b. Re-install the cover to the battery box.
c. Re-install the breakaway pin
(b)
into the brake switch.
d. Connect the trailer wiring plug to the tow vehicle.
Result
The procedure to test the breakaway system is now complete.
wc_gr008515
d
VDC
1000
200
20
2
200m
F
V
A
V-
COM
Summary of Contents for G 230
Page 1: ...5000186930 09 0215 5 0 0 0 1 8 6 9 3 0 Operator s Manual Mobile Generator G 230 G 240 EN ...
Page 6: ...Foreword 6 wc_tx003565gb_FM10 fm Notes ...
Page 178: ...wc_tx003849gb_FM10 fm 178 Engine Maintenance John Deere 4045TF285 HF285 6068HF285 770051 ...
Page 179: ...wc_tx003849gb_FM10 fm 179 Engine Maintenance John Deere 4045TF285 HF285 6068HF285 770052 ...
Page 180: ...wc_tx003849gb_FM10 fm 180 Engine Maintenance John Deere 4045TF285 HF285 6068HF285 770048 ...
Page 184: ...wc_tx003663gb_FM10 fm 184 Engine Maintenance T4i Cummins QSB6 7 770016 ...
Page 211: ...wc_tx003111gb_FM10 fm 211 User s Information for Transport Canada Fuel Tank ...
Page 212: ...wc_tx003111gb_FM10 fm 212 User s Information for Transport Canada Fuel Tank ...
Page 252: ......
Page 253: ......