![Wacker Neuson E3000 Operator'S Manual Download Page 88](http://html2.mh-extra.com/html/wacker-neuson/e3000/e3000_operators-manual_3125736088.webp)
ghi_tx001162gb.fm
88
Accessories
E 3000
5.7
Connecting Six HX 50 Heat Exchangers
Requirements
Six HX 50 Heat Exchangers
Four 2-1 adapters
Three 1-2 adapters
One Single Pump Pack (SPP)
Auxiliary Pump Pack (APP) (See topic
Mounting the Auxiliary Pump Panel.
)
Connect
adapters
Perform the procedure below to connect the Heat Exchanger to the machine.
1. Connect a 2-1 adapter
(x)
to the left return plumbing rack
(LR)
.
2. Connect a 2-1 adapter
(y)
to 2-1 adapter
(x)
.
3. Connect a 1-2 adapter
(z)
to left accessory supply
(LS)
.
4. Connect a 2-1 adapter
(w)
to the right return plumbing rack
(RR)
.
5. Connect a 2-1 adapter
(u)
to 2-1 adapter
(w)
.
6. Connect a 1-2 adapter
(v)
to right accessory supply
(RS)
.
Connect the
SPP
1. Position the SPP
(g)
near the machine.
2. Connect hose
(i)
to the supply port of the SPP and to valve #1 of the machine.
3. Connect a 1-2 adapter
(h)
to the outlet port of the SPP.
4. Open valve #1.
Connect the
HX hoses
1. Position the Heat Exchangers
(a
thru
f)
within the space to be heated.
2. Connect Heat Exchanger
(a)
to 1-2 adapter
(z)
and 2-1 adapter
(x)
.
3. Connect Heat Exchanger
(b)
to 1-2 adapter
(z)
and 2-1 adapter
(y)
.
4. Connect Heat Exchanger
(c)
to 1-2 adapter
(v)
and 2-1 adapter
(y)
.
5. Connect Heat Exchanger
(d)
to 1-2 adapter
(v)
and 2-1 adapter
(u)
.
6. Connect Heat Exchanger
(e)
to 1-2 adapter
(h)
and 2-1 adapter
(u)
.
7. Connect Heat Exchanger
(f)
to 1-2 adapter
(h)
and 2-1 adapter
(w)
.
Complete the
installation
1. Insulate the supply and return hoses.
2. Connect the Heat Exchangers to the appropriate electrical source.
3. Connect the SPP power cord to the APP.
4. Open cross-connect valve #5.
5. Close valve #4 and valve #6.
This procedure continues on the next page.
Summary of Contents for E3000
Page 6: ...Foreword wc_tx002028gb fm 6...
Page 39: ...ghi_tx001160gb fm 39 E 3000 Lifting and Transporting Notes...
Page 77: ...wc_tx001951gb fm 77 E 3000 Operation Notes...
Page 97: ...ghi_tx001162gb fm 97 E 3000 Accessories wc_gr008560 a b LR RR RS LS HX 50 HX 50...
Page 99: ...ghi_tx001162gb fm 99 E 3000 Accessories wc_gr008561 a LR LS HX 50...
Page 103: ...ghi_tx001162gb fm 103 E 3000 Accessories wc_gr008582 HX 100 HX 100 a b LR RR LS RS...
Page 105: ...ghi_tx001162gb fm 105 E 3000 Accessories wc_gr008583 HX 100 a LR LS...
Page 182: ...MSDS Dowfrost HD 50...
Page 186: ...wc_tx001673gb fm 186 Fuji Temperature Controller...
Page 199: ...Tire Safety Information...
Page 201: ...wc_tx001952gb fm 201 E 3000 Schematics 12 2 Composite Schematic Machine with Gas Burner...
Page 205: ...wc_tx001952gb fm 205 E 3000 Schematics 12 4 Circulation System Circuit...
Page 206: ...wc_tx001952gb fm 206 Schematics E 3000 12 5 Rewind System Circuit...
Page 207: ...wc_tx001952gb fm 207 E 3000 Schematics 12 6 Gas Train Schematic...
Page 208: ...wc_tx001952gb fm 208 Schematics E 3000 12 7 Generator...
Page 213: ......