wc_tx001951gb.fm
63
E 3000
Operation
4.22
Unwinding and Positioning the Hoses
Requirements
HTF preheated if applicable
HTF flow initiated
Procedure
Follow the procedure below to unwind and position the hoses.
1. Rotate the T-handle
(a)
counter-clockwise to unlock it.
:
2. Pull the hose
(b)
off the reel by hand and place it in the application area. See
topic
Hose Spacing Guidelines
for hose spacing recommendations based on
application.
Result
The hose is now positioned and the machine is operating.
NOTICE:
The machine must be periodically monitored during operation to ensure
system efficiency. See topic
Monitoring the Operating Parameters
.
CAUTION
Burn hazard. The hoses and components of the plumbing system may be very hot.
Hot hoses and hot plumbing components may cause burns.
f
Wear gloves when handling hot hoses and plumbing components.
wc_gr008535
wc_gr008530
Summary of Contents for E3000
Page 6: ...Foreword wc_tx002028gb fm 6...
Page 39: ...ghi_tx001160gb fm 39 E 3000 Lifting and Transporting Notes...
Page 77: ...wc_tx001951gb fm 77 E 3000 Operation Notes...
Page 97: ...ghi_tx001162gb fm 97 E 3000 Accessories wc_gr008560 a b LR RR RS LS HX 50 HX 50...
Page 99: ...ghi_tx001162gb fm 99 E 3000 Accessories wc_gr008561 a LR LS HX 50...
Page 103: ...ghi_tx001162gb fm 103 E 3000 Accessories wc_gr008582 HX 100 HX 100 a b LR RR LS RS...
Page 105: ...ghi_tx001162gb fm 105 E 3000 Accessories wc_gr008583 HX 100 a LR LS...
Page 182: ...MSDS Dowfrost HD 50...
Page 186: ...wc_tx001673gb fm 186 Fuji Temperature Controller...
Page 199: ...Tire Safety Information...
Page 201: ...wc_tx001952gb fm 201 E 3000 Schematics 12 2 Composite Schematic Machine with Gas Burner...
Page 205: ...wc_tx001952gb fm 205 E 3000 Schematics 12 4 Circulation System Circuit...
Page 206: ...wc_tx001952gb fm 206 Schematics E 3000 12 5 Rewind System Circuit...
Page 207: ...wc_tx001952gb fm 207 E 3000 Schematics 12 6 Gas Train Schematic...
Page 208: ...wc_tx001952gb fm 208 Schematics E 3000 12 7 Generator...
Page 213: ......