wc_tx001951gb.fm
73
E 3000
Operation
4.29
Operating States of the Beckett Burner Controller
Burner states
The burner control has several states that it sequences through during normal
operation. These operating states are described below.
.
Standby
Run
Ignition
carryover
State
10
30
Operating
wc_gr007662
State
Action or Function
Standby
As soon as power is supplied to the burner control, the burner control
enters the standby state in which it will remain until there is a call for
heat or power is disconnected.
Valve-on
delay
(pre-time)
When the setpoint of the temperature controller is set to a temperature
higher than that of the heat transfer fluid, the output contacts of the tem-
perature controller close, completing a circuit between the two terminals
labeled “T” of the burner control. This is the call for heat. The burner
control enters the valve-on-delay state.
The valve-on-delay state lasts 15 seconds. During this state:
Power is sent to the burner motor/fuel pump.
Power is sent to the electrodes.
If the cad cell detects flame at the end of the valve-on-delay state, the
burner control goes into the lockout state.
Trial-for-
ignition
The trial-for-ignition state immediately follows the valve-on-delay state.
During this state:
The fuel shut-off valve is opened (energized).
Pressurized fuel atomizes at the burner nozzle.
The atomized fuel is ignited by the electrodes.
The burner fires and the flame is monitored by the cad cell.
If flame is detected, the burner control moves to the ignition carryover
state.
If flame is not detected within 15 seconds:
The burner control enters the lockout state.
Power is disconnected from the fuel shut-off valve, electrodes, and
the burner motor.
Summary of Contents for E3000
Page 6: ...Foreword wc_tx002028gb fm 6...
Page 39: ...ghi_tx001160gb fm 39 E 3000 Lifting and Transporting Notes...
Page 77: ...wc_tx001951gb fm 77 E 3000 Operation Notes...
Page 97: ...ghi_tx001162gb fm 97 E 3000 Accessories wc_gr008560 a b LR RR RS LS HX 50 HX 50...
Page 99: ...ghi_tx001162gb fm 99 E 3000 Accessories wc_gr008561 a LR LS HX 50...
Page 103: ...ghi_tx001162gb fm 103 E 3000 Accessories wc_gr008582 HX 100 HX 100 a b LR RR LS RS...
Page 105: ...ghi_tx001162gb fm 105 E 3000 Accessories wc_gr008583 HX 100 a LR LS...
Page 182: ...MSDS Dowfrost HD 50...
Page 186: ...wc_tx001673gb fm 186 Fuji Temperature Controller...
Page 199: ...Tire Safety Information...
Page 201: ...wc_tx001952gb fm 201 E 3000 Schematics 12 2 Composite Schematic Machine with Gas Burner...
Page 205: ...wc_tx001952gb fm 205 E 3000 Schematics 12 4 Circulation System Circuit...
Page 206: ...wc_tx001952gb fm 206 Schematics E 3000 12 5 Rewind System Circuit...
Page 207: ...wc_tx001952gb fm 207 E 3000 Schematics 12 6 Gas Train Schematic...
Page 208: ...wc_tx001952gb fm 208 Schematics E 3000 12 7 Generator...
Page 213: ......