Troubleshooting the Machine
Problem / Symptom
Reason
Remedy
Thaw progress is below
capacity.
The insulation is insuffi-
cient.
Add additional insulation
blankets.
The moisture is insufficient.
Verify that there is standing
water on job site.
There is no vapor barrier.
Lay down vapor barrier.
The HTF is not flowing.
Verify that the pump pres-
sure is nominal and hoses
are not restricted.
The temperature control is
not set properly.
Set the temperature control
to optimum setting. This
setting depends on environ-
mental conditions at the job
site.
The soil conditions are not
as expected.
Re-evaluate thawing plan
based on job site condi-
tions.
Pump will not start.
There is no power.
Verify that the breaker
switch is ON. Verify that the
HTF level is within range
and low level cutoff control
is reset (low level indicator
light must be OFF).
The HTF temperature is
below -26°C (-15°F).
Warm the HTF and hoses
before starting machine;
see topic
Preheating the
Heat Transfer Fluid (HTF)
in
this manual.
Hose rewind does not work.
The hose reel brake is not
fully released.
Fully release the hose reel
brake.
The motor temperature is
below nominal value
(<18°C (0°F)).
Warm the enclosure by run-
ning the machine with all
doors closed
or
warm the
enclosure using an exter-
nal heat source.
The foot pedal switch has
failed.
Replace the foot pedal
switch.
Summary of Contents for E3000
Page 6: ...Foreword wc_tx002028gb fm 6...
Page 39: ...ghi_tx001160gb fm 39 E 3000 Lifting and Transporting Notes...
Page 77: ...wc_tx001951gb fm 77 E 3000 Operation Notes...
Page 97: ...ghi_tx001162gb fm 97 E 3000 Accessories wc_gr008560 a b LR RR RS LS HX 50 HX 50...
Page 99: ...ghi_tx001162gb fm 99 E 3000 Accessories wc_gr008561 a LR LS HX 50...
Page 103: ...ghi_tx001162gb fm 103 E 3000 Accessories wc_gr008582 HX 100 HX 100 a b LR RR LS RS...
Page 105: ...ghi_tx001162gb fm 105 E 3000 Accessories wc_gr008583 HX 100 a LR LS...
Page 182: ...MSDS Dowfrost HD 50...
Page 186: ...wc_tx001673gb fm 186 Fuji Temperature Controller...
Page 199: ...Tire Safety Information...
Page 201: ...wc_tx001952gb fm 201 E 3000 Schematics 12 2 Composite Schematic Machine with Gas Burner...
Page 205: ...wc_tx001952gb fm 205 E 3000 Schematics 12 4 Circulation System Circuit...
Page 206: ...wc_tx001952gb fm 206 Schematics E 3000 12 5 Rewind System Circuit...
Page 207: ...wc_tx001952gb fm 207 E 3000 Schematics 12 6 Gas Train Schematic...
Page 208: ...wc_tx001952gb fm 208 Schematics E 3000 12 7 Generator...
Page 213: ......