wc_tx001951gb.fm
64
Operation
E 3000
4.23
Hose Spacing Guidelines
Background
When laying hose in the application area, the space between individual lines of
hose significantly affects the progress of the application. Although it is impossible
to predict the ambient conditions for each job site, Wacker Neuson Corporation
recommends observing the following guidelines to maximize efficiency.
Hose spacing
diagram
Refer to the diagram and table below when placing hoses in the application area.
Note:
Adjustments may be necessary to achieve maximum efficiency.
Note:
To increase heat penetration, cover the hoses with a plastic vapor barrier
and two layers of insulated blankets. For concrete curing, cover the concrete with
plastic, place the hoses on top of the plastic, then cover the hoses with two layers
of insulated blankets.
Note:
The hoses may be positioned vertically along concrete framing walls for
curing applications. Contact Wacker Neuson Application Support for more
information.
Application
Distance (d)
Description
Frost prevention
91.5 cm (36 in.)
Prevents frost in the application area.
Concrete curing
61 cm (24 in.)
Allows concrete to cure.
Excavation thaw
61 cm (24 in.)
Partially thaws the ground for excavation.
Compaction thaw
45.7 cm (18 in.)
Completely thaws the ground for compaction.
Accelerated thaw
30.5 cm (12 in)
Up to 50% faster than compaction thaw.
Summary of Contents for E3000
Page 6: ...Foreword wc_tx002028gb fm 6...
Page 39: ...ghi_tx001160gb fm 39 E 3000 Lifting and Transporting Notes...
Page 77: ...wc_tx001951gb fm 77 E 3000 Operation Notes...
Page 97: ...ghi_tx001162gb fm 97 E 3000 Accessories wc_gr008560 a b LR RR RS LS HX 50 HX 50...
Page 99: ...ghi_tx001162gb fm 99 E 3000 Accessories wc_gr008561 a LR LS HX 50...
Page 103: ...ghi_tx001162gb fm 103 E 3000 Accessories wc_gr008582 HX 100 HX 100 a b LR RR LS RS...
Page 105: ...ghi_tx001162gb fm 105 E 3000 Accessories wc_gr008583 HX 100 a LR LS...
Page 182: ...MSDS Dowfrost HD 50...
Page 186: ...wc_tx001673gb fm 186 Fuji Temperature Controller...
Page 199: ...Tire Safety Information...
Page 201: ...wc_tx001952gb fm 201 E 3000 Schematics 12 2 Composite Schematic Machine with Gas Burner...
Page 205: ...wc_tx001952gb fm 205 E 3000 Schematics 12 4 Circulation System Circuit...
Page 206: ...wc_tx001952gb fm 206 Schematics E 3000 12 5 Rewind System Circuit...
Page 207: ...wc_tx001952gb fm 207 E 3000 Schematics 12 6 Gas Train Schematic...
Page 208: ...wc_tx001952gb fm 208 Schematics E 3000 12 7 Generator...
Page 213: ......