Accessories
5.6
Using Heat Exchangers to Heat Air
Background
The E 3000 can be combined with Wacker Neuson HX 50, HX 100, or HX 200 Heat
Exchangers to convert the heating application from surface to air.
Configuration
requirements
In order to connect Heat Exchangers to the machine, additional accessories (Sin-
gle Pump Packs (SPP), Dual Pump Pack (DPP), or Auxiliary Pump Panel (APP)
may be required to support the additional load on the machine’s systems. Use the
chart below to determine what components may be required.
NOTICE:
Use care when adding accessories; failure to adhere to these require-
ments may damage your machine.
Limitations
Maximum run (horizontal distance from HX to machine): 228 m (750 ft)
Maximum rise (vertical distance of HX above machine): 76 m (250 ft)
Maximum run at maximum rise: 215 m (707 ft)
Note:
The farther the HX is positioned from the parent machine, the more heat will
be lost through the hose. This may affect HX performance.
Heat Exchanger
Model
Qty
Additional components required
SPP
DPP
1-2
Adapter
2-1
Adapter
APP
HX 50
1
—
—
—
—
—
2
—
—
—
—
—
3
—
—
1
1
—
4
—
—
1
2
—
5
1
—
2
3
1
6
1
—
3
4
1
HX 100
1
—
—
—
—
—
2
—
—
—
—
—
3
1
—
1
—
1
HX 200
1
—
—
—
—
—
2
—
1
—
1
1
0 – 76 m (250 ft)
0 – 228 m (750 ft)
0 – 215 m (707 ft)
wc_gr008096
Summary of Contents for E3000
Page 6: ...Foreword wc_tx002028gb fm 6...
Page 39: ...ghi_tx001160gb fm 39 E 3000 Lifting and Transporting Notes...
Page 77: ...wc_tx001951gb fm 77 E 3000 Operation Notes...
Page 97: ...ghi_tx001162gb fm 97 E 3000 Accessories wc_gr008560 a b LR RR RS LS HX 50 HX 50...
Page 99: ...ghi_tx001162gb fm 99 E 3000 Accessories wc_gr008561 a LR LS HX 50...
Page 103: ...ghi_tx001162gb fm 103 E 3000 Accessories wc_gr008582 HX 100 HX 100 a b LR RR LS RS...
Page 105: ...ghi_tx001162gb fm 105 E 3000 Accessories wc_gr008583 HX 100 a LR LS...
Page 182: ...MSDS Dowfrost HD 50...
Page 186: ...wc_tx001673gb fm 186 Fuji Temperature Controller...
Page 199: ...Tire Safety Information...
Page 201: ...wc_tx001952gb fm 201 E 3000 Schematics 12 2 Composite Schematic Machine with Gas Burner...
Page 205: ...wc_tx001952gb fm 205 E 3000 Schematics 12 4 Circulation System Circuit...
Page 206: ...wc_tx001952gb fm 206 Schematics E 3000 12 5 Rewind System Circuit...
Page 207: ...wc_tx001952gb fm 207 E 3000 Schematics 12 6 Gas Train Schematic...
Page 208: ...wc_tx001952gb fm 208 Schematics E 3000 12 7 Generator...
Page 213: ......