![Wacker Neuson E3000 Operator'S Manual Download Page 74](http://html2.mh-extra.com/html/wacker-neuson/e3000/e3000_operators-manual_3125736074.webp)
wc_tx001951gb.fm
74
Operation
E 3000
Ignition
carryover
The ignition carryover state starts as soon as the flame is established.
During this state:
The fuel shut-off valve is open (energized).
Pressurized fuel atomizes at the burner nozzle.
The atomized fuel is ignited by the electrodes.
The electrodes stay powered for up to 10 seconds after flame is
sensed.
When the ignition carryover state has elapsed:
The ignition transformer is shut off.
The burner control enters the run state.
If the flame is lost during the ignition carryover state:
If the lockout time has not expired, the burner control returns to trial-
for-ignition state.
If the lockout time has expired, the burner control enters the recycle
mode.
Run
The run state starts and continues once the ignition carryover state has
elapsed. During this state:
The fuel shut-off valve is open (energized).
Pressurized fuel atomizes at the burner nozzle.
The flame is monitored by the cad cell.
When the setpoint is reached (call for heat satisfied), the burner control
enters the burner-motor-off delay state.
If the flame is lost during the run state:
The burner control enters the recycle mode.
Burner-motor-
off-delay
The burner-motor-off-delay state starts immediately after the setpoint is
reached, i.e., the call for heat has been satisfied. The time of this state
is 30 seconds. During this state:
The output contacts of the temperature controller open, interrupting
the circuit between terminals labeled “T”.
The fuel shut-off valve closes (de-energizes).
The burner motor runs until the burner-motor-off delay expires, then
the burner motor turns off.
The burner control returns to the idle mode.
If the cad cell detects flame during the burner-motor-off-delay state:
The burner control goes into the standby state.
State
Action or Function
Summary of Contents for E3000
Page 6: ...Foreword wc_tx002028gb fm 6...
Page 39: ...ghi_tx001160gb fm 39 E 3000 Lifting and Transporting Notes...
Page 77: ...wc_tx001951gb fm 77 E 3000 Operation Notes...
Page 97: ...ghi_tx001162gb fm 97 E 3000 Accessories wc_gr008560 a b LR RR RS LS HX 50 HX 50...
Page 99: ...ghi_tx001162gb fm 99 E 3000 Accessories wc_gr008561 a LR LS HX 50...
Page 103: ...ghi_tx001162gb fm 103 E 3000 Accessories wc_gr008582 HX 100 HX 100 a b LR RR LS RS...
Page 105: ...ghi_tx001162gb fm 105 E 3000 Accessories wc_gr008583 HX 100 a LR LS...
Page 182: ...MSDS Dowfrost HD 50...
Page 186: ...wc_tx001673gb fm 186 Fuji Temperature Controller...
Page 199: ...Tire Safety Information...
Page 201: ...wc_tx001952gb fm 201 E 3000 Schematics 12 2 Composite Schematic Machine with Gas Burner...
Page 205: ...wc_tx001952gb fm 205 E 3000 Schematics 12 4 Circulation System Circuit...
Page 206: ...wc_tx001952gb fm 206 Schematics E 3000 12 5 Rewind System Circuit...
Page 207: ...wc_tx001952gb fm 207 E 3000 Schematics 12 6 Gas Train Schematic...
Page 208: ...wc_tx001952gb fm 208 Schematics E 3000 12 7 Generator...
Page 213: ......