The CoreSense module has power applied at all times to allow for more detailed fault
notification. An LED will flash when a fault occurs. The number of flashes will identify the
fault condition.
# of Flashes
Condition
1
Oil Pressure
2
Motor Protection Trip
3
Discharge Temperature (optional add-on)
4
Current Sensor Fault
5
Communication Error
FIGURE 9-11A
CoreSense Protection
Description
Vogt #
Copeland #
Crankcase Heater
100 W (insert type)
518-0028-01
Oil Pressure safety switch
Sentronic3
Module and Sensor
585-1076-02
CoreSense Protection
Module and Sensor
943-0109-00
Oil safety – sensor only
For Sentronic, Sentronic 3
or CoreSense
998-0162-00
Control Circuit Protection.
The electrical control circuit of the machine is protected by a 2 pole 3
amp circuit breaker. If breaker trips, the machine will immediately stop. Before resetting the
breaker, open the disconnect switch to machine and set the “Ice/Off/Clean” switch to the “Off”
position. If the machine was off for an extended time the crankcase heater must be energized for a
minimum of two hours before restarting the machine. When ready to restart the machine, depress
the “Start” button. The machine will automatically return to a freeze cycle upon completion of the
harvest cycle.
3
22
22
6
Summary of Contents for P118F/HE100
Page 4: ...Vogt Tube Ice Machines Installation Service Manual and Parts Catalog 12A4171M06 05TA Model ...
Page 10: ...05TA Service Manual TABLE OF CONTENTS vi ...
Page 20: ...05TA Service Manual INTRODUCTION 7 19 13 1 10 ...
Page 40: ...05TA Service Manual INSTALLING YOUR TUBE ICE MACHINE 3 7 14 3 18 BLANK PAGE ...
Page 50: ...5 6 5TA Service Manual START UP AND OPERATION 7 19 13 Blank page ...
Page 106: ...05TA Service Manual SERVICE OPERATIONS 3 10 14 9 28 Blank ...
Page 114: ...Blank page ...
Page 115: ...05TA Service Manual TABLES CHARTS 3 10 14 11 1 11 Tables Charts ...