![Vogt P118F/HE100 Service Manual Download Page 65](http://html.mh-extra.com/html/vogt/p118f-he100/p118f-he100_service-manual_1044454065.webp)
05TA Service Manual
MAINTENANCE
7/19/13
7-7
Vent Plug
Drain Plug
Oil Level Plug
Vent Plug
Compressor
HP
Oil Charge
(oz)
3DT3R & 3DTHR
10
125
4DE3R
(50hz machines before 2013)
12
135
TABLE 7-3
Compressor Oil Capacity
An oil pump should be used to force any oil that may be required into the system. Oil may be added
to the compressor through the low pressure test connection adjacent to the high/low pressure switch
or through the compressor suction service valve. The compressor suction service valve should be
“backseated” to shut off pressure to the gauge port when connecting the oil pump. Air should be
purged from the oil pump discharge line by forcing some oil through the line before tightening the
charging connection.
Cutter Gear Reducer.
The oil level for the gear reducer should be checked if there is evidence of a
leak. It should be level with the plugged opening in the side of the gear housing. Use Mobile 600W
cylinder oil or equal. Change oil once a year.
Note: Ventless gear reducer used after August 2010
FIGURE 7-2
Gear Reducer
Gear Reducer (10:1)
Part #:
Replacement food grade oil:
Part #: 19T3020C01
Texaco Cygnus 220
Oil Capacity: 8 ounces
Summary of Contents for P118F/HE100
Page 4: ...Vogt Tube Ice Machines Installation Service Manual and Parts Catalog 12A4171M06 05TA Model ...
Page 10: ...05TA Service Manual TABLE OF CONTENTS vi ...
Page 20: ...05TA Service Manual INTRODUCTION 7 19 13 1 10 ...
Page 40: ...05TA Service Manual INSTALLING YOUR TUBE ICE MACHINE 3 7 14 3 18 BLANK PAGE ...
Page 50: ...5 6 5TA Service Manual START UP AND OPERATION 7 19 13 Blank page ...
Page 106: ...05TA Service Manual SERVICE OPERATIONS 3 10 14 9 28 Blank ...
Page 114: ...Blank page ...
Page 115: ...05TA Service Manual TABLES CHARTS 3 10 14 11 1 11 Tables Charts ...