05TA Service Manual
INSTALLING YOUR TUBE-ICE
®
MACHINE
3/7/14
3-15
Ice Bin Thermostat Sensor
An electronic ice bin thermostat may be added to automatically
cycle machine operation. To assure proper protection for the machine or auxiliary equipment, the
sensor of the ice bin thermostat must be located so that ice will contact it when the bin is full (See
FIGURE 3-8 for typical mounting bracket). The distance between the top of the ice bin and the
sensor allows space for the machine to make an additional discharge of ice AFTER the ice contacts
the probe. This will vary based on the size of the bin and the ice distribution system employed.
Note:
The probe should also be mounted on the back side of the bracket, opposite of the front of the
bin to reduce the possibility of damage from ice removal equipment.
The control panel is electrically connected so that the bin thermostat will stop the machine only upon
the completion of a harvest period.
FIGURE 3-8
Typical Bin Sensor Mounting
Note:
Actual location of
sensor will vary based on bin layout and ice distribution system.
STAINLESS
STEEL
ANGLE
NOTE: Use front of
angle to protect
probe
Summary of Contents for P118F/HE100
Page 4: ...Vogt Tube Ice Machines Installation Service Manual and Parts Catalog 12A4171M06 05TA Model ...
Page 10: ...05TA Service Manual TABLE OF CONTENTS vi ...
Page 20: ...05TA Service Manual INTRODUCTION 7 19 13 1 10 ...
Page 40: ...05TA Service Manual INSTALLING YOUR TUBE ICE MACHINE 3 7 14 3 18 BLANK PAGE ...
Page 50: ...5 6 5TA Service Manual START UP AND OPERATION 7 19 13 Blank page ...
Page 106: ...05TA Service Manual SERVICE OPERATIONS 3 10 14 9 28 Blank ...
Page 114: ...Blank page ...
Page 115: ...05TA Service Manual TABLES CHARTS 3 10 14 11 1 11 Tables Charts ...