![Vogt P118F/HE100 Service Manual Download Page 84](http://html.mh-extra.com/html/vogt/p118f-he100/p118f-he100_service-manual_1044454084.webp)
05TA Service Manual
SERVICE OPERATIONS
2/18/14
9-6
Solenoid Valves.
All solenoid valves are pilot operated with “floating” type diaphragms. For
satisfactory operation be sure that the manual opening stem is in the closed or automatic position. This
means the stem is backed all the way out. Correct direction of stem rotation should be labeled on the
stem seal nut.
FIGURE 9-6A
“X” Solenoid Valve (Sporlan ME34S290)
Air cooled machines before August 2006
FIGURE 9-6B
“X” Solenoid Valve (Sporlan ME35S190)
Air cooled machines only after August 2006
Table 9-1
Sporlan Valve Part #’s
Vogt #
Sporlan
Rebuild Kit #
Coil #
12A4200A0904
ME34S290
– KS-E34
– MKC-2
ME35S190
– KS-E35
12A2105C28 – MKC-1
Note: Manual stem not shown
Sporlan 1 1/8” Solenoid Valve
Vogt Part #: 12A4200A0904
Sporlan #: ME34S290
Sporlan 1 1/8” Solenoid Valve
Vogt Part #:
Sporlan #: ME35S190
Summary of Contents for P118F/HE100
Page 4: ...Vogt Tube Ice Machines Installation Service Manual and Parts Catalog 12A4171M06 05TA Model ...
Page 10: ...05TA Service Manual TABLE OF CONTENTS vi ...
Page 20: ...05TA Service Manual INTRODUCTION 7 19 13 1 10 ...
Page 40: ...05TA Service Manual INSTALLING YOUR TUBE ICE MACHINE 3 7 14 3 18 BLANK PAGE ...
Page 50: ...5 6 5TA Service Manual START UP AND OPERATION 7 19 13 Blank page ...
Page 106: ...05TA Service Manual SERVICE OPERATIONS 3 10 14 9 28 Blank ...
Page 114: ...Blank page ...
Page 115: ...05TA Service Manual TABLES CHARTS 3 10 14 11 1 11 Tables Charts ...